No. | Test Item | Instrument Name | Price for Ours | Price for Others | |||||||||
Inorganic Geochemistry Lab
Contact:Peijun Qiao, Tel:021-65984279, Email:qiaopeijun@tongji.edu.cn | |||||||||||||
1 | Major Elements | ICP-OES(IRIS Advantage) | ¥150 /sample | ¥300 /sample | |||||||||
2 | Elements/Ca Ratios of Foraminifer | ICP-MS(VGX7) | ¥120 /sample | ¥240 /sample | |||||||||
3 | Trace Elements | ¥250 /sample | ¥400 /sample | ||||||||||
4 | Major Elements + Trace elements | ICP-OES+MS | ¥300 /sample | ¥600 /sample | |||||||||
Organic Geochemical Analysis Lab
Contact:Lingdi Chen,Tel:021-20926957-1011, Email:lingdichen@tongji.edu.cn | |||||||||||||
5 | Quantitative and Qualitative Analysis of Organic Compounds | GC (Agilent, 6890N), GC(Thermo, Trace DSQ ) | (pretreatment +50) | ¥150 /sample (pretreatment +100) | |||||||||
GC-MS(Thermo, TSQ8000) | ¥200 /sample (pretreatment +50) | ¥400 /sample (pretreatment +100) | |||||||||||
Triple Quad LC/MS (Agilent,6460), Quadrupole LC/MS(Agilent,6130) | ¥200 /sample (pretreatment +50) | ¥400 /sample (pretreatment +100) | |||||||||||
6 | Compound-specific Stable Carbon, Nitrogen and Hydrogen Isotope Analysis | Stable Isotope Ratio Mass Spectrometry equipped with GC(Deltaplus XP IRMS) Stable Isotope Ratio Mass Spectrometry equipped with GC(MAT253 IRMS) | ¥200 /sample (duplicate analysis +100) | ¥400 /sample (duplicate analysis +200) | |||||||||
7 | Bulk Carbon and Nitrogen Iisotope Analysis | Stable Isotope Ratio Mass Spectrometry equipped with EA(Deltaplus XP IRMS) | ¥100 /sample (duplicate analysis +100;simultaneous analysis for both isotopes +50) | ¥200 /sample (duplicate analysis +150;simultaneous analysis for both isotopes+80) | |||||||||
8 | Carbon and Nitrogen Abundance Analysis | Organic Elemental Analyzer (Elementar Vario EL Cube) | ¥80 /sample | ¥160 /sample | |||||||||
Stable Isotope Ratio Mass Spectrometer Lab
Contact:Xiaoying Jiang, Tel:021-65984819, Email:jiangxy@tongji.edu.cn | |||||||||||||
9 | Foraminifer | Stable Isotope Ratio Mass Spectrometer(Finnigan-MAT252/MAT253) | ¥80 /sample | ¥160 /sample | |||||||||
Other Carbonate
| ¥100 /sample | ¥200 /sample | |||||||||||
Electron Microprobe and Scanning Electron Microscope Lab
Contact:Lingmin Zhang, Tel:021-20926959-1011, Email: zlm@tongji.edu.cn | |||||||||||||
10 | Images (SE,BSE,CL) | Field Emission Scanning Electron Microscope (TESCAN MIRA3 LMU) | Analysis | ¥200 /h | ¥400 /h | ||||||||
Carbon/gold coating | ¥100 /sample | ¥200 /sample | |||||||||||
11 | Images (SE,BSE,CL) and Composition analysis | Field Emission Scanning Electron Microscope (TESCAN MIRA3 LMU) and Oxford Ultim Max40 EDS | Analysis | ¥250 /h | ¥500 /h | ||||||||
Carbon/gold coating | ¥100 /sample | ¥200 /sample | |||||||||||
12 | Images (SE,BSE,CL) and Composition analysis | Electron Microprobe Analyzer (JEOL JXA-8230), and Oxford Energy Dispersive Spectrometer (EDS) | Analysis (> 8 Hours) | ¥3000 /day | ¥6000 /day | ||||||||
Analysis (< 8 Hours) | ¥300 /h | ¥600 /h | |||||||||||
Carbon/gold coating | ¥100 /sample | ¥200 /sample | |||||||||||
Sedimentology Laboratory
Contact:Yanli Li, Tel:021-20926967-1022, Email:yanlili@tongji.edu.cn | |||||||||||||
13 | Clay Mineralogy Analysis (preparation and data processing included) | X-Ray Diffractometer(XRD)PANalytical X’Pert PRO | ¥150 /sample | ¥300 /sample | |||||||||
Bulk Mineralogy Analysis (data processing excluded) | ¥250 /sample | ¥500 /sample | |||||||||||
14 | Element Geochemistry Analysis | X-Ray Fluorescence (XRF) Spectrometer PANalytical AxiosMAX | ¥150 /sample | ¥300 /sample | |||||||||
15 | Grain Size Analysis | Laser Grain Size Analyzer Coulter LS230 | ¥50 /sample | ¥100 /sample | |||||||||
16 | Grain Size Analysis | Sedimentation Particle Size Analyzer SediGraph III Plus | ¥150 /h | ¥300 /h | |||||||||
Core Scanning Lab
Contact:Xiaofang Xu, Tel:021-20926953-1011, Email: xxf@tongji.edu.cn | |||||||||||||
17 | Core scanning (1cm resolution) | XRF core scanner(AVAATECH) | ¥500 /m | ¥1000 /m | |||||||||
Seismic Data Processing Contact:Yuzhu Liu, Tel:021-65984723, Email:liuyuzhu@tongji.edu.cn | |||||||||||||
18 | High Performance Computing System | HP PC Cluster | ¥0.2 /Core Hour | ¥0.4 /Core Hour | |||||||||
LA-MC-ICPMS Lab (Elemental, Isotopic and Laser Analysis)
Contact:Juan Xu, Tel:021-20926972-1022, Email:juanxu@tongji.edu.cn | |||||||||||||
19 | Sr Isotopes | MC-ICPMS(Neptune plus) | ¥900 /sample | ¥1100 /sample | |||||||||
20 | Nd Isotopes | MC-ICPMS(Neptune plus) | ¥900 /sample | ¥1100 /sample | |||||||||
21 | Sample Digestion and Trace Elements Analysis | ICPMS(Agilent 7900) | ¥300 /sample | ¥500 /sample | |||||||||
22 | Sample Digestion | Pre-treatment in the clean lab | ¥150 /sample | ¥300 /sample | |||||||||
23 | H-O Isotopes Analysis | H-O isotopic analyzer (LGR: TIWA-45 EP) | Salinity<1, ¥90 /sample Salinity≥1, ¥150 /sample | Salinity<1, ¥180 /sample salinity≥1, ¥300 /sample | |||||||||
24 | Trace Elements in Minerals | ICPMS(Agilent 7900)、LA(Resolution 193nm) | ¥80 /spot | ¥120 /spot | |||||||||
Trace Elements in Carbonate | ¥80 /spot | ¥120 /spot | |||||||||||
U-Pb Dating and Trace Elements Analysis for Zircons | ¥80 /spot | ¥120 /spot | |||||||||||
Paleomagnetism Laboratory
Contact:Weiwei Chen, Tel: 021-20926959-1011, Email:sww@tongji.edu.cn | | ||||||||||||
25 | Stepwise Thermal Demagnetization | Long-core Superconducting Rock magnetometer (2G755 4K)/Dual Speed Spinner magnetometer (JR6A); High-capacity Single-chamber Thermal Demagnetizer (TD-48SC) | ¥300 /sample | ¥600 /sample | | ||||||||
26 | Stepwise Alternating Field Demagnetization | Long-core Superconducting Rock magnetometer (2G755 4K)/Dual Speed Spinner magnetometer (JR6A); Alternating Field Demagnetizer (D2000) (including the long-core) | ¥150 /sample ¥1500 /m | ¥300 /sample ¥2000 /m | | ||||||||
27 | Magnetic Susceptibility Anisotropy (AMS) | Multi-Function Kappabridge (MFK1-FA) | ¥6 /sample | ¥20 /sample | | ||||||||
28 | The Temperature Dependence of Magnetic Susceptibility (k-T) | Multi-Function Kappabridge (MFK1-FA) | ¥150 /sample | ¥200 /sample | | ||||||||
29 | The Curve of Isothermal Remanent Magnetization | Dual Speed Spinner magnetometer (JR6A); Impulse Magnetizer (DPM1) | ¥30 /sample | ¥90 /sample | | ||||||||
30 | The Remanence Measurement of Single Step (directional specimen) | Dual Speed Spinner magnetometer (JR6A) | ¥15 /sample | ¥45 /sample | | ||||||||
31 | The Remanence Measurement of Single Step (non-directional specimen) | Dual Speed Spinner magnetometer (JR6A) | ¥5 /sample | ¥15 /sample | | ||||||||
32 | Magnetic Susceptibility | Multi-Function Kappabridge (MFK1-FA) | ¥2 /sample | ¥6 /sample | | ||||||||
Environmental Radioactivity Lab
Contact:Daidu Fan, Tel:021-65989073, Email:ddfan@tongji.edu.cn | | ||||||||||||
33 | Assay of Radioactive Source Material to Identify the Isotopes Present (e.g. 210Pb, 137Cs, 226Ra, 228Ra and 234Th.) | Low-background well-type High-Purity Germanium (HPGe) radiation detection system (GWL-120-15-LB-AWT, AMETEK, USA) | ¥300 /day | ¥600 /day | | ||||||||
Nannofossil Lab
Contact:Xiaobo Jin, Tel:15618196733, Email: 386jinxiaobo@tongji.edu.cn | | ||||||||||||
34 | Coccolith Identification and Counting | Leica DM6000B polarized microscope | ¥200 /sample | ¥400 /sample | | ||||||||
35 | Coccolith Identification and Counting | Zeiss AX10 polarized microscope +AxioCam MRc5 digital camera | ¥200 /sample | ¥400 /sample | | ||||||||
36 | Pretreatment for Coccolith Geochemistry | Leica DM6000B polarized microscope | ¥200 /sample | ¥400 /sample | | ||||||||
Specific Surface Area and Gas Adsorption Lab (SSA-GA Lab)
Contact:Xiaojun Zhu, Tel:15900785893, Email:xjzhu@tongji.edu.cn | | ||||||||||||
37 | High-temperature and Pressure Gas Adsorption | PCTPro high-temperature and -pressure gas adsorption analyzer | Pressure: <120 bar | ¥4000 /isotherm | ¥6000 /isotherm | | |||||||
Pressure: 120~200 bar | ¥6000 /isotherm | ¥9000 /isotherm | | ||||||||||
38 | Low temperature Nitrogen Adsorption | AutoSorb-iQ gas adsorption analyzer | BET SSA | ¥300 /sample | ¥500 /sample | | |||||||
Adsorption & Desorption isotherm | ¥1000 /sample | ¥1400 /sample | | ||||||||||
39 | Ethylene Glycol Monoethyl Ether (EGME) Adsorption | EGME adsorption apparatus | <30 samples | ¥400 /sample | ¥600 /sample | | |||||||
>30 samples | ¥300 /sample | ¥500 /sample | |
Rock Physics Lab
Contact:Jiqiang Ma, Tel:021-20926972-1022, Email:ma_jiqiang@tongji.edu.cn | ||||
40 | Ultrasonic Velocity Measurement for Consolidated Sample | SCMS-F High/low temperature and high pressure core-plug measure system (only for well-prepared sample and including five pressure point records) | ¥1200 /sample | |
44 | Resistivity Measurement for Consolidated Sample | SCMS-F High/low temperature and high pressure core-plug measure system (only for well-prepared samples and including five pressure point records) | ¥400 /sample | ¥600 /sample |
42 | Porosity Measurement with Different Confining Pressure for Consolidated Sample | SCMS-F High/low temperature and high pressure core-plug measure system (only for well-prepared samples and including five pressure point records) | ¥300 /sample | ¥500 /sample |
43 | Permeability Measurement with Different Confining Pressure for Consolidated Sample | SCMS-F High/low temperature and high pressure core-plug measure system (only for well-prepared samples and including five pressure point records) | ¥400 /sample | 600 /sample |
44 | Resistivity Index Measurement for Consolidated Sample | SCMS-F High/low temperature and high pressure core-plug measure system (only for well-prepared samples) | ¥800 /sample | ¥1200 /sample |
45 | Unconsolidated Sample Measurement (Gas hydrate simulation, ultrasonic velocities and conductivity measurement) | SCMS-F High/low temperature and High pressure core-plug measure system (only for well-prepared samples) | ¥10000 /sample | |
Marine Chemistry Lab
Contact:Yushuang Zhang, Tel:021-20926959-1011, Email: zysgem@tongji.edu.cn | ||||
46 | Microelement Analysis of Solid Samples (measure distance is up to 4μm, measure area is up to 190mm*160mm) | High Performance Micro XRF Spectrometer(Bruker M4 Tornado) | ¥250 /h | ¥500 /h |
Exceeds 8 h and less than 24 h in one day will be charged daily. Internal price: ¥2000 /day; Full price: ¥4000 /day | ||||
47 | Organic Matter Analysis of Polycyclic Aromatic Hydrocarbons, Hormone etc. and Inorganic Matter Analysis of Sulfide, Thiosulfate etc. | High Performance Liquid Chromatograph(Waters e2695 Alliance) | ¥60 /sample | ¥120 /sample |
¥150 /h | ¥300 /h | |||
48 | Total Organic Carbon and Total Nitrogen in Liquid and Solid Samples | Total Organic Carbon/Nitrogen Analyzer (analytikjena Multi N/C® 3100) | ¥50 /sample | ¥100 /sample |
¥150 /h | ¥300 /h | |||
49 | Determination of Trace Elements such as Iron, Manganese, Copper, Plumbum, Zinc and Chromium in Water, Particulate Matter and Sediments | Atomic Absorption Spectrometer (Perkin Elmer PinAAcle 900T) | ¥50 /sample | ¥100 /sample |
¥150 /h | ¥300 /h | |||
50 | Fluorescence Observation of Living Cells, Microscopic Imaging, etc. | Inverted Fluorescence Microscope (Leica DMI 4000B) | ¥140 /h | ¥280 /h |
51 | Microscopic Observation and Photography of Any Material | Digital Microscope(Leica DM6 M) | ¥130 /h | ¥260 /h |
52 | Microscopic Observation and Photography of Rock and Mineral Thin Sections and Biological Thin Sections Under Fluorescence Condition | Polarizing Microscope (Leica DM 4500P) | ¥140 /h | ¥280 /h |
53 | Stereoscopic Microscope | Stereoscopic Microscope (Leica M125) | ¥130 /h | ¥260 /h |
54 | Efficient and Rapid Separation of Suspended Samples, DNA Extraction, etc. | High Efficiency Centrifuge (BECKMAN COULTER Avanti J-26 XP) | ¥175 /h | ¥350 /h |
55 | Freeze-dry Samples | Vacuum Freeze Drier (CHRIST ALPHA 1-2 LD plus) | ¥160 /day | ¥320 /day |